Merrill's Product Catalog: Pitless Units, Kits, Adapters
Cut a piece of 1/2" pipe (see chart) and flatten one end to fit stainless steel screw inside pitless body, for custom wrench. (see custom tool shown below)

Thread pipe from pump to brass or stainless steel pitless body by putting wrench on pipe and pitless body, NOT pull pipe above pitless body.

Apply Anti-Seize/Gasket Lube to O-ring seal and then lower into casing.

When lowering unit into casing, line up mark on support bar with notch or mark cut in top of casing.
Turn stainless steel screw inside pitless body clockwise using custom wrench until O-ring seal on inner wall of casing.
Complete installation by installing watertight cap on top of well casing, model depends on state well code. MCU or SSMCU Pitless Unit is now installed.
Pulling Pump - Before pulling pump make sure that the stainless steel screw on pitless body inside pull pipe is turned (counter-clockwise) so the back lever can pivot in as far as necessary.
Connect to support bar center threads and lift.
 
Custom Tool available from factory, welds on to 1/2" pipe for turning stainless steel screw.
Back to Top