| Home || Product Catalog || About Merrill MFG. || Contact Us |
| Merrill's Product Catalog: Floats, Air Volume Controls | |||||||||||||||
| Tank Accessories | |||||||||||||||
| Merrill Air Valves | |||||||||||||||
| Merrill Bleeder Orifices | |||||||||||||||
| Merrill Pressure Relief Valves
|
|||||||||||||||
|
|||||||||||||||
| Pressure Relief Valves | ||||
| Recommended for all cold water system installations - to protect against damage to piping and pressure tanks. PRV are set at 75 psi or 100 psi- adjustable from 75 to 150 psi. PRV have a +/- 15% setting accuracy. PRVHD are set at 75 psi. PRVHD's are field adjustable and recommended for use up to 300 psi on water systems only. These valves are not T&P valves that are required with water heaters. There is the same need for PRV on cold water pressure tanks. | ||||
| Order No. | UPC Bar Code (Qty. 1) |
Inlet x Outlet | Ctn. Qty. | Ctn. Wt./Lbs. |
| Merrill PRV Valves are field adjustable - by removing cap and turning brass screw down to increase. | ||||
| *PRV50 | 6 42367 02251 8 | 1/2" x 1/2" | 10 | 3.5 |
| PRV75 | 6 42367 02252 5 | 3/4" x 1/2" | 10 | 3.8 |
| PRV757 | 6 42367 02253 2 | 3/4" x 3/4" | 10 | 3.9 |
| *A perfect companion to Merrill Galvanized Tank Tees 1X, 100X, 102X, and 125X | ||||
| Merrill PRV Valves are field adjustable - by removing cap and turning brass screw down to increase. | ||||
| •PRV50100 | 6 42367 11074 1 | 1/2" x 1/2" | 10 | 3.5 |
| •PRV75100 | 6 42367 11075 8 | 3/4" x 1/2" | 10 | 3.8 |
| •PRV757100 | 6 42367 11076 5 | 3/4" x 3/4" | 10 | 3.9 |
| •Note: Above valves set at 100 psi. | ||||
| Merrill PRVHD Valves can be field adjusted to a custom setting upon request. Custom set relief valves are non-cancelable and non returnable. | ||||
| PRVHD75 | 6 42367 04304 9 | 3/4" x 3/4" | 1 | 1.6 |
| PRVHD100 | 6 42367 04305 6 | 1" x 1" | 1 | 2.6 |
| PRVHD125 | 6 42367 04306 3 | 1-1/4" x 1-1/4" | 1 | 4.3 |
| PRVHD150 | 6 42367 05387 1 | 1-1/2" x 1-1/2" | 1 | 5.5 |
| PRVHD200 | 6 42367 05388 8 | 2" x 2" | 1 | 8.9 |
| Back to Top | ||||
| PVC Pressure Relief Valves | |||||
| Order No. | UPC Bar Code (Qty. 1) |
Inlet x Outlet | Ctn. Qty. | Ctn. Wt./Lbs. | ![]() |
| PVCPRV50 | 6 42367 11391 9 | 1/2" MIP x 1/2" FIP | 1 | .20 | |
| Back to Top | |||||
| No-Lead Pressure Relief Valves | |||||
| Order No. | UPC Bar Code (Qty. 1) |
Inlet x Outlet | Ctn. Qty. | Ctn. Wt./Lbs. | Merrill No-Lead PRVNL Valves are field adjustable - by removing cap and turning brass screw down to increase. |
| PRVNL50 | 6 42367 08885 9 | 1/2" x 1/2" | 10 | 3.5 | |
| PRVNL75 | 6 42367 08886 6 | 3/4" x 1/2" | 10 | 3.8 | |
| Back to Top | |||||
| Domestic Heavy-Duty Adjustable Pressure Relief Valves | |||||
| Order No. | UPC Bar Code (Qty. 1) |
Inlet x Outlet | Ctn. Qty. | Ctn. Wt./Lbs. | Heavy-duty pressure relief valves available, factory set at 5 psi to 300 psi. Special order, non-stock item. |
| DPRV50 | 6 42367 09301 3 | 1/2" x 1/2" | 1 | 2.3 | |
| DPRV75 | 6 42367 09302 0 | 3/4" x 3/4" | 1 | 2.3 | |
| DPRV100 | 6 42367 09303 7 | 1" x 1" | 1 | 3.5 | |
| DPRV125 | 6 42367 09304 4 | 1-1/4" x 1-1/4" | 1 | 5.0 | |
| DPRV150 | 6 42367 09305 1 | 1-1/2" x 1-1/2" | 1 | 6.3 | |
| DPRV200 | 6 42367 09306 8 | 2" x 2" | 1 | 11.0 | |
| Back to Top | |||||
![]() |
|
| Note: | Merrill pressure relief valves may not reseat themselves after pressure relief if subjected to extreme conditions. Manual disassembly and reseating of valve may be required. Valve is not defective if required. |
| Back to Top | |
| ©2008 Merrill MFG. All rights reserved. Site Design by: | ||